Environmental Chamber
| 6010 |
Temperature and RH |
[details] [pdf] |
| |
10 cu.ft., 5C to 70C, 20 to 98%RH |
|
| 6030 |
Temperature and RH |
[details] [pdf] |
| |
30 cu.ft., 5C to 70C, 20 to 98%RH |
|
| 6033 |
Heat Only |
[details] [pdf] |
| |
30 cu. ft., 5C above ambient to 60C
|
|
Temperature & Humidity
|
|
 |
 |
| |
Downloads
Click here to download product literature |
|
 |
 |
 |
The CARON 6010 and 6030 Environmental Test Chambers feature humidification and refrigeration capabilities to create repeatable environmental conditions for numerous applications including: product shelf life, stability and package testing, light exposure and temperature evaluation studies, electronic component burn-in, TAPPI testing, photostability, plant growth, and insect rearing.
The chambers utilize environmentally friendly HFC refrigerant and CFC-Free insulation, and are designed to meet NEC, UL and CSA standards for safety and performance. As with all CARON constant temperature equipment, both models are fully covered by our 12-month parts and labor warranty.
Standard and Optional Features
Environmental Test Chambers
Models 6010 and 6030
Standard Control Features
- Temperature with humidification for precise repeatable conditions
- Microprocessor based PID controllers with autotune
- Solid state relative humidity sensor
- Stainless steel sheath RTD temperature probe
- LED temperature display with 0.1°C resolution
- LED RH% display with 1% resolution
- Audible and visual temperature alarms to alert any temperature deviation from active set point of exceeding high limit
- Non-volatile memory allows chamber to return to original setpoint when power is restored, in the event of a power failure
- Temperature and humidity controllers show two separate displays while operating: one for process and one for setpoint
Standard Cabinet Features
- Stainless steel interior
- One 2" access port, two fresh air vents
- Horizontal airflow
- Model 6010 Key lockable interior glass door and exterior solid door
- Model 6030 Key lockable full view glass door
- Model 6030 Interior electrical outlet
- Redundant high temperature safeties
Optional Features and Accessories
- Model 6010:Light package, four 20 Watt fluorescent lights, 2 per shelf on 2 of the four shelves, includes cycle timer for day/night temperature settings
- Model 6030: Light package, eight 20 Watt fluorescent lights, 2 per shelf on 4 of the five shelves, includes cycle timer for day/night temperature settings
- IQ/OQ validation services available
- Computer communications: PC-based remote interface software to log data, and to set and adjust control panel from a remote terminal or personal computer
- Temperature and RH% controller with field configurable Ramp/Soak programs
- Independent product temperature safety with digital display, audible and visual alarms, and thermocouple for the product/sample being tested
- Model 6010: 4 swivel casters, 2 locking, 2 standard swivel
- Circular chart recorder, temperature and relative humidity, 2-pen, 10 inch, 7 day, 0 to 70°C, side or wall mounted
- Heatless dryer package, purge air system using compressed air to lower the RH% levels
- Additional wire rod shelves and/or solid stainless steel shelves
- Additional interior electrical outlet
- Extended temperature ranges down to 0°C with defrost cycle option
- International voltages, 50Hz, CE compliance (consult factory for details)
- Model 6030: Light tight door cover
- Installation, start-up & training packages available
- Tighter temperature and humidity control available
Chamber Specifications
Environmental Test Chambers
Model 6010 and 6030
| Temperature Range without Lights |
5ºC to 70ºC |
5ºC to 70ºC |
| Temperature Range with Lights |
10° to 70° |
10° to 70° |
| Temperature Control |
± 0.1°C |
±0.1°C |
| Temperature Uniformity |
± 0.3°C |
±0.3°C |
| Relative Humidity |
20 to 98% RH* |
20 to 98% RH* |
| Humidity Control |
± 3% |
± 2% |
| Interior Dimensions |
23"W x 25.8"D x 29.8"H
(58.4cm x 65.5cm x 75.7cm) |
30"W x 27.5"D x 63.5" H
(76.2 cm x 69.9 cm x 161.3 cm) |
| Exterior Dimensions |
44.2"W x 32.6"D x 36.5"H
(112.3cm x 82.8cm x 92.7 cm) |
36.9"W x 37"D x 90.3" H**
(93.7 cm x 94 cm x 229.4 cm) |
| Work Space |
10 cu. ft. (283.2 liters) |
30 cu. ft. (850 liters) |
| Shelves |
|
|
| Number of Shelves |
4 stainless steel, wire rod |
5 stainless steel, wire rod |
| Shelf Spacing |
1.5" on center (15 positions) |
1.5" on center (37positions) |
| Shelf Size |
Each Shelf: 22.8"W x 25.4" D
(57.9cm x 64.5cm) |
Each Shelf: 29.25"W x 26.5"D
(74.3 cm hhx 67.3 cm) |
| Shelf Area |
4 ft.2 each, 16 ft2 total |
5.4 ft2 each, 26.9 ft2 total |
| Materials/Finishes: |
|
|
| Interior Cabinets |
All stainless steel |
All stainless steel |
| |
Interior Door - tempered glass |
|
| Exterior |
Exterior Cabinet - powder coated metal |
Exterior Cabinet - powder coated metal |
| |
Exterior Door - aluminum, powder coat finish |
Exterior Door - triple pane glass door |
| Feet |
Adjustable leveling glides |
Adjustable leveling glides |
| Electrical |
Model 6010-1 115V, 60Hz
Model 6010-2 208/230V, 60 Hz
Model 6010-3 230V, 50 Hz |
Model 6030-1 115V, 60Hz
Model 6030-2 208/230V, 60 Hz
Model 6030-3 230V, 50 Hz |
| Shipping Weight |
400 lbs (181 kgs) |
750 lbs (340 kgs) |
| Warranty |
12 month parts & labor |
12 month parts & labor |
|
*RH levels limited by 4°C minimum dewpoint. Specifications were established at 20°C with 50% RH ambient conditions, 115VAC, 60 Hz, without lights.
**Can be adapted to fit through smaller doorways. Consult factory for details.
50 Hz models carry the CE mark.
Note: Specifications subject to change without notice. |
Performance Charts
Available Accessories for Model 6030
| Catalog No. |
Name |
Unit of Issue |
Models |
| ALRM202 |
Remote Alarm Contacts |
Each |
6010, 6011, 6012, 6030, 6031, 6032 |
| |
Remote alarm contacts for 6010 and 6030 Series. Provides NO and NC dry contacts for alarms. |
 |
| CNTC101 |
Contact Closure |
Each |
6010, 6030 |
| |
Contact closure dual setpoint system. Allows temperature and humidity to switch between two setpoints. |
 |
| CNTR113 |
Controller |
Each |
6010, 6030 |
| |
Watlow Ramp & Soak Controller with RS485 communications |
 |
| CRSY102 |
Condensate Recirculator |
Each |
6010, 6030, 6034, 6035, 6105, 6545 |
| |
Condensate recirculating system most commonly used with the chamber when necessary in-house water supply or floor drain is unavailable, or as an attempt to conserve water usage. Collects, filters, and reuses water as the unit calls for humidity. |
 |
| CRSYKIT |
Condensate Circulator Kit |
Each |
6010, 6030, 6034, 6035, 6105, 6545 |
| |
Tubing and fitting kit to connect CRSY102 to two chambers. |
 |
| DEFR201 |
Defrost Package |
Each |
6010, 6030 |
| |
Defrost package for operation down to 0C. |
 |
| DOOR505 |
Door |
Each |
6030, 6031, 6033, 6034, 6035 |
| |
Solid light tight door cover |
 |
| DOOR506 |
Door |
Each |
6030, 6031, 6032 |
| |
Solid insulated door (no glass) |
 |
| DRYR109 |
Dryer Package |
Each |
6010, 6030 |
| |
Heatless dryer package, purge air system. Allows for operation of the chamber at lower humidity levels (2% RH). Utilizes 90 to 150 psi compressed air. |
 |
| FLTR101 |
Filter |
Each |
6010, 6030, 6034, 6035, 6105, 6545 |
| |
Filter replacement kit for CRSY102. Includes DI cartridge, carbon filter, and silver stick. |
 |
| GLVPRT |
Glove Port |
Each |
6030 |
| |
Custom door with glove ports for Model 6030 |
 |
| INSTALLATION |
Installation |
Each |
6010, 6011, 6012, 6030, 6031, 6032, 6033, 6034, 6035 |
| |
Installation & start-up. Facility must already be equipped with electrical and plumbing requirements. |
 |
| LGHT102 |
Light |
Each |
6030 |
| |
Light package for Model 6030. Includes (8) 20 Watt fluorescent bulbs and a 24 hour timer for day/night simulations. |
 |
| LGHT103 |
Light |
Each |
6030, 6035 |
| |
LED lighting system. Includes (12) LED lighting strips located on side walls of chamber and a 24 hour timer for day/night simulations. |
 |
| LGHT111 |
Light |
Each |
6010, 6030 |
| |
Light upgrade to D65 lights. Replaces standard fluorescent bulbs in the light package. |
 |
| LGHT601 |
UV Germicidal Lamp |
Each |
6010, 6030, 6034, 6035, 6105, 6545 |
| |
Ultraviolet germicidal lamp deactivates microorganisms, for CRYS102 |
 |
| PORT103 |
Access Port |
Each |
6010, 6030 |
| |
Additional 2" access port |
 |
| RCDR103 |
Recorder |
Each |
6010, 6030, 6034, 6035, 6545 |
| |
Temperature/humidity recorder. Honeywell, 2 pen, 7 day, 10" circular chart. |
 |
| RCDR111 |
Recorder |
Each |
6010, 6030, 6034, 6035, 6545 |
| |
Built-in temperature recorder. Cobex, 2 pen, 24 hour or 7 day, 6" circular chart. |
 |
| RCDR202 |
Recorder |
Each |
6010, 6030, 6035 |
| |
Circular, 12", Honeywell Truline Chart Recorder. Records and charts two variables. |
 |
| SFTW102 |
Software |
Each |
6010, 6011, 6012, 6030, 6031, 6032, 6033, 6034 |
| |
Windows-based Watlow communications software for data logging. |
 |
| SHKR101 |
Shaker Support System |
Each |
6030, 6034 |
| |
Stainles Steel Triple-Tier Shaker Support System. Capable of supporting up to three 150 lb. shakers operating at 150 RPM each. 19" clearance between shelves. Complete with two 115V GFI duplex outlets. Standard leveling feet on chambers are replaced with vibration isolation pads when ordering this option. |
 |
| SHLF100 |
Shelf |
Each |
6030, 6031, 6032 |
| |
Additional 6030 series stainless steel perforated shelf. Includes 4 shelf clips. |
 |
| SHLF101 |
Shelf |
Each |
6030, 6031, 6032 |
| |
Additional 6030 series stainless steel wire rod shelf . Includes 4 shelf clips. |
 |
| SHLF102 |
Shelf |
Each |
6030, 6031, 6032 |
| |
Additional 6030 series stainless steel solid shelf. Includes 4 shelf clips. |
 |
| SVC-603 |
Service Manual |
Each |
6030 |
| |
Service manual for 6030 chamber, provides drawings, schematics, and instructions for routine maintenance and troubleshooting. |
 |
| VLD-600 |
IQ/OQ Protocol |
Each |
6010, 6030 |
| |
Installation & operation qualification protocol |
 |
| VLD-601 |
Full Validation |
Each |
6010, 6030 |
| |
Full on site IQ/OQ/PQ validation, includes calibration of controllers, controller functionality testing, 12-hour empty chamber temperature mapping, 12-hour empty chamber humidity uniformity (where applicable) mapping, and comprehensive final summary report. |
 |
|
|