Photostability Chamber
| 6540 |
Photostability Chamber, ICH Q1B, Option 2 |
[details] [pdf] |
| |
10C to 35C, 2 Shelves, Fluorescent (Near UV and Cool White) |
|
| 6545 |
Photostability Chamber, ICH Q1B, Option 2 |
[details] [pdf] |
| |
10C to 35C, 40-70% RH, 2 Shelves, Fluorescent (Near UV and Cool White) |
|
Photostability Chambers
Models 6540-1, 6545-1, 6540-2, 6545-2, 6540-3 & 6545-3
 |
 |
 |
| |
Downloads
Click here
to download product literature
|
|
 |
 |
 |
The 6540 Series Photostability chambers were specifically designed to perform near UV and visual light testing with fluorescent lamps per ICH Q1B Guidelines, Option 2. This second generation benchtop unit controls light and temperature conditions through an easy-to-use color touch-screen interface. Lights automatically shut off after a specified exposure level or time duration. Uniform light distribution and high intensity levels allow quick response for forced degradation testing and confirmatory studies. Precise humidity control (Models 6545-1, 6545-2 & 6545-3) is achieved through ultrasonic injection and mechanical refrigeration methods.
As with all CARON manufactured products, chambers sold in North America are fully covered by our 12-month standard warranty agreement. Installation and validation services are also available. Please contact your local international distributor for warranty and validation services in other areas.
Standard Features
- Independent control of near UV and cool white VIS lamps are provided to eliminate overexposure for confirmatory tests and provide flexibility for forced degradation studies.
- In "Automatic" mode, lights turn off at the end of a programmed exposure or timed test.
- "Manual" mode allows a flexible test time duration and makes validating the chambers easy.
- Dimmable lamps (230V models) allow testing at specific light intensity levels.
- Programmable alarms notify the user when aging lamps should be replaced.
- Specular aluminum reflective surfaces provide uniform UVA & VIS light reflection and maintain proper SPD (spectral power distribution).
- Stainless steel interior construction provides a smooth, non-porous surface for easy maintenance.
- Two light detectors (one VIS and one UVA) with an integral radiometer are standard and provide precise and accurate light intensity measurements. Light detectors are both cosine corrected and calibrated to NIST traceable standards.
- Precise temperature control is provided through use of a PID controller.
- Humidity controlled units (Models 6545-1, 6545-2 & 6545-3) isolate the effects of hydration during photostability testing.
- Shelves slide out for quick and easy loading and unloading of samples.
- Strategic lamp spacing provides enhanced light uniformity. Overhead lighting results in a large illumination area for maximized direct lighting.
- Door safety switch turns lights off when the door is opened. The lockable door prevents additional disturbance of in-process tests.
- Two access ports (one per shelf) are standard.
Main Screen Display
- Performance is managed through an eye level, icon-based, color, touch-screen interface for user convenience.
- The easy-to-use controls are written in multiple languages (English, Spanish, German and French).
- Temperature, humidity, and light meters can be quickly programmed. Test results are easy to interpret.
- Pull-out, removable light banks allow for quick bulb replacement without the use of tools.
- Modular refrigeration system and front access, slide-out electrical chassis are easy to service.
- Units contain off-the-shelf components that are readily available.
Product Specifications
| Model |
6540-1 |
6545-1 |
6540-2 |
6545-2 |
6540-3 |
6545-3 |
| Lamp Type, UVA |
Fluorescent, near UV (black lamp) |
| Lamp Type, VIS |
Fluorescent, cool white (ISO 10977 compliant) |
| Light Detectors |
UVA and Visual, calibrated |
| UVA Light Intensity, Typical |
20 W/m2 |
2-30 W/m2 |
| VIS Light Intensity, Typical |
20 klux |
2-35 klux |
| Lamps Dimming |
n/a |
3-100% |
Typical Time Required to Reach ICH
Recommendation of 200 W-hr/m2 |
10 hrs. |
7 hrs. |
Typical Time Required to Reach ICH
Recommendation of 1.2 million lux-hr |
60 hrs. |
35 hrs. |
| Light Uniformity |
UVA: ±10%
VIS: ±15% |
UVA: ±10%
VIS: ±15% |
| Temperature Range |
10°C to 35°C (lights on) |
| Temperature Control |
± 0.2°C (lights on) |
| Temperature Uniformity |
± 2.5°C (lights on) |
| Humidity Range |
n/a |
40-70% RH |
n/a |
40-70% RH |
n/a |
40-70% RH |
| Humidity Control |
n/a |
± 3% |
n/a |
± 3% |
n/a |
± 3% |
| # of Shelves, Size |
Two (2) sliding, 26.0" W x 23.1" D x 8.0" H
(660mm W x 587mm D x 203mm H) each |
| Usable Shelf Area, Each |
19.0" x 23.0" (483mm x 584mm) |
| Usable Shelf Area, Total |
6.1 sq. ft. (0.56 m2) per shelf; 76% of total shelf |
| Maximum Weight per Shelf |
22 lbs. (10 kg) |
| Interior Surfaces |
Reflective Specular Aluminum |
| Interior Construction |
Stainless Steel |
| Internal Volume |
10.5 sq. ft. (296L), includes lamp space |
|
Exterior Dimensions |
37.6" W x 30.2" D x 46.0" H w/leveling feet
(955mm W x 767mm D x 1168mm H) |
| Interior Dimensions |
26.9" W x 24.0" D x 28.0" H
(683mm W x 610mm D x 711mm H) |
| # of Access Ports |
Two (2), 1.75" W x 2.0" H each
(44mm W x 51mm H) |
| Shipping Weight |
700 lbs. (900 lbs. with export crate) |
| Electrical Service |
115V, 60 Hz, 15A |
208/230V, 60 Hz, 15A |
230V, 50 Hz, 10A |
Specifications are subject to change without notice. Specifications were established with lights fully on at 20°C, with 20°C and 50% RH ambient conditions. RH levels limited by a 6°C minimum dewpoint. 50 Hz units are CE Marked and contain readily available components.
To view our "Using Photostability Test Chambers to Meet the Requirements of Drug Testing in Accordance with ICH Q1B" white paper, click here.
Available Accessories for Model 6545
| Catalog No. |
Name |
Unit of Issue |
Models |
| CART102 |
Laboratory Equipment Cart |
Each |
6010, 6011, 6012, 6540, 6545 |
| |
Heavy duty, 48"x30"x24"H, laboratory euqipment cart. Reinforced, removable, heavy-duty, solid 12 ga. aluminum top. Aluminum undershelf provides convenient storage space. 5" stem-type casters with brakes. Accommodates equipment up to 800 lbs. |
 |
| CRSY102 |
Condensate Recirculator |
Each |
6010, 6030, 6034, 6035, 6105, 6545 |
| |
Condensate recirculating system most commonly used with the chamber when necessary in-house water supply or floor drain is unavailable, or as an attempt to conserve water usage. Collects, filters, and reuses water as the unit calls for humidity. |
 |
| CRSYKIT |
Condensate Circulator Kit |
Each |
6010, 6030, 6034, 6035, 6105, 6545 |
| |
Tubing and fitting kit to connect CRSY102 to two chambers. |
 |
| EXTD005 |
Extended Temp Range |
Each |
6540, 6545 |
| |
Extended temperature down to +5C (with lights on) |
 |
| EXTD045 |
Extended Temp/RH Range |
Each |
6545 |
| |
Extended temperature up to +45C. Extended humidity range to 80%. (light bank removed) |
 |
| FLTR101 |
Filter |
Each |
6010, 6030, 6034, 6035, 6105, 6545 |
| |
Filter replacement kit for CRSY102. Includes DI cartridge, carbon filter, and silver stick. |
 |
| LGHT503 |
Replacement Lamps |
Each |
6540, 6545 |
| |
Black light bank replacement kit for 115V models. Includes (6) 20 Watt lamps. |
 |
| LGHT504 |
Replacement Lamps |
Each |
6540, 6545 |
| |
White light bank replacement kit for 115V models. Includes (10) 35 Watt lamps. |
 |
| LGHT505 |
Replacement Lamps |
Each |
6540, 6545 |
| |
Black light bank replacement kit for 230V models. Includes (6) 18 Watt lamps. |
 |
| LGHT506 |
Replacement Lamps |
Each |
6540, 6545 |
| |
White light bank replacement kit for 230V models. Includes (14) 18 Watt lamps. |
 |
| LGHT601 |
UV Germicidal Lamp |
Each |
6010, 6030, 6034, 6035, 6105, 6545 |
| |
Ultraviolet germicidal lamp deactivates microorganisms, for CRYS102 |
 |
| RCDR103 |
Recorder |
Each |
6010, 6030, 6034, 6035, 6545 |
| |
Temperature/humidity recorder. Honeywell, 2 pen, 7 day, 10" circular chart. |
 |
| RCDR111 |
Recorder |
Each |
6010, 6030, 6034, 6035, 6545 |
| |
Built-in temperature recorder. Cobex, 2 pen, 24 hour or 7 day, 6" circular chart. |
 |
| RCDR204 |
Recorder |
Each |
6545 |
| |
Circular, 12", Honeywell Truline Chart Recorder. Records and charts four variables. |
 |
| TABL101 |
Stainless Steel Work Table |
Each |
6540, 6545, 6010, 6011, 6012 |
| |
Heavy-duty Laboratory Equipment Cart (48"x30"x35"H). Cabinet base has sliding doors, 1-1/4" turn down lip on four sides, 14 ga. stainless steel top, adjustable legs, and undershelf. Shipped fully assembled. |
 |
| VLD-640 |
IQ/OQ Protocol |
Each |
6540, 6545 |
| |
Protocol for installation and operation qualification (IQ/OQ), in professional binder. |
 |
| VLD-641 |
Full Validation |
Each |
6540, 6545 |
| |
Full on-site IQ/OQ/PQ validation. Uses VLD-640 protocol (included). |
 |
|
|